Fusion CRF Technical Details
Fusion CRF is a patented technology that works by combining Radio frequency and Cavitational High-Frequency waves to achieve a powerful synergy able to penetrate deeper into the skin and affect the deeper dermis and subcutaneous layers, causing tightening and improvements to the underlying tissue structure.
The Fusion CRF device is a state-of-the-art RF heating and cavitational source for aesthetic and cosmetic applications. The Fusion CRF consists of a 350-watt Radiofrequency generator that operates in a frequency of 1-7 MHz range and a High-Frequency wave generator that operates in a frequency of 40-50 KHz. The differentiating factor between the Fusion CRF system and other Radiofrequency devices is versatile treatment applications.
Through the use of both monopolar and stable cavitation phenomena, deep and superficial uniform heating can be delivered to tighten the skin and to break down fat in the interstitial tissue. This stimulates fat drainage, while concurrently the thermo-electric coupling tip cooler protects the epidermis.
The result is a non-surgical, non-laser, user-friendly device that consistently provides:
- Immediate collagen contraction
- Long-term collagen remodeling
- Elimination of cellulite symptoms
- Reduction of fat store
- Superficial and deep dermal heating
- No patient recovery time
- Outpatient treatment
Device Components
The Fusion CRF System includes these technical features:
Radiofrequency Generator
Ultrasound Generator
Face Tightening Monopolar Handpieces
Body RF Monopolar Handpiece
Combined Cavitational and RF Monopolar Body Handpiece
Consumable Products
Vacuum And Thermo-Electric Coupling
Radiofrequency Generator
The RF generator produces up to 7 MHZ radiofrequency signal regulated by a microprocessor capable to receive constant feedback from the handpiece tip, including temperature, treatment application energy and tissue contact with the tip.
The RF generator itself is simple and efficient to operate; controls are within easy reach and important user information is clearly displayed on the color LCD display, including energy delivered, tissue temperature and treatment setting.
Ultrasound Generator
The Ultrasound generator produces 40-50 KHz and involves the transformation of electrical energy into low frequency sound waves that are transmitted into the tissues by the handpiece to create a mechanical vibration.
It is similar to the energy produced by a vibrating tuning fork, just that it is a higher frequency, and not audible. It is called ultrasonic because these sound waves are just above the upper limit of human hearing.
Face and Body Monopolar Handpieces
Both face and body, monopolar handpieces contain advanced sensors that process information about skin temperature and contact, treatment energy density, cooling system function and other important data. A thermo-electric coupling cooler within the handpiece ice cools the tip and helps to protect the epidermal surface. Combined Cavitational and RF Monopolar Body Handpiece
The CRF (cavitational radiofrequency) handpiece combines low frequency ultrasound waves to create a mechanical vibration and disrupt fibrosis and fat cells, and radiofrequency energy to generate deep and superficial uniform heating to tighten and contour both the skin and underlying tissue.
Effects of low-frequency ultrasound waves
Mechanical
- Micro-massage
- Fibrosis breakage
- Improves cellular metabolism
- “Cavitation” – increases cell membrane permeability
Thermal
- Increases circulation of blood & lymph
- Stimulates cellular metabolism
Chemical
- The breakdown of complex molecules
- Thermo-electric coupling tip cooler
To achieve simultaneous heating and cooling, the thermo-electric coupling tip cooler transmits energy to the skin while serving as a contact cooling for the epidermis. The contact plate continually monitors skin surface temperature to safeguard the skin.
Consumable Products
Each patient will require own return RF pad when the procedure is performed. The return pad is adhered to the patient’s lower back to allow a path of travel for the radiofrequency current back to the generator.
A sophisticated solid gel tip, which delivers a controlled amount of RF energy, a viscous liquid that helps ensure electrical and thermal contact with the tip device, an antiseptic skin cleanser and a desensitizing skin fluid are also provided.
Technical Specification
- Radiofrequency: Frequency 1 – 7 MHz
- Ultrasound: Frequency 40 – 50 KHz
- Up to 350 Watts
- 220 – 110VAC +/- 10%, 60 Hz
- 1 – 10 seconds or continuous Electrical
- 30kg
- 740 mm L x 560 mm D x 1360 mm H, Weight 75 Kg